Evoluzion Photoluminescent

 

STANDARD DIN europe

 

Category A

The products of category A they will have high luminance and they were used preferably for signs and beacons of places of public concentration or with exclusively artificial illumination.

 

Badges and Sheets

Characteristic

Photoluminiscent under laboratory conditions

Luminance 10 minutes ≥ 20 mcd/m2 Luminance 60 minutes ≥ 2,8 mcd/m2 Time of decadence ≥ 340 minutes

Composition and preservatives

Material plastic autoextinguishable or metallic had of photoluminiscent and appreciable lead (low 0,01%)

 

Category B

The products of category B will have smaller luminance that those A and they are rotted to use for the rest of uses.

 

Badges and Sheets

Same characteristics and procedures that it stops tipologia A, except:

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance 10 minutes ≥ 15 mcd/m2 Luminance 60 minutes ≥ 2,2 mcd/m2 Time of decadence ≥ 320 minutes

 

Pigments Photoluminiscents

Characteristic

Photoluminiscent under laboratory conditions

Luminance 10 minutes ≥ 28 mcd/m2 Luminance 60 minutes ≥ 3,4 mcd/m2 Time of decadence ≥ 340 minutes

Composition and preservatives

Inorganic pigments of sulfurate of zinc or aluminatos without appreciable lead (low 0,01%)

 

Category A

Tiles, Enamel, Molds and Continuous Perfil

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 15 mcd/m2 Luminance a 60 minutes ≥ 1,6 mcd/m2 Time of decadence ≥ 220 minutes

Composition and preservatives

Ceramic cookie or had ceramic sandstone of photoluminiscent and appreciable lead (low 0,01%)

 

Category B

Tiles, Enamel, Molds and Continuous Perfil

Same characteristics and procedures that it stops tipologia A, except:

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 10 mcd/m2 Luminance a 60 minutes ≥ 1,2 mcd/m2 Time of decadence ≥ 180 minutes

 

Category A

Paintings and inks

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 20 mcd/m2 Luminance a 60 minutes ≥ 2,8 mcd/m2 Time of decadence ≥ 340 minutes

Composition and preservatives

Pigmentos inorgánicos con resinas

Camera of saline fog

Without decrease of 5% it has more than enough values of luminance to the 96 hours of exhibition

Radioactivity

<74 kBq /kg

 

Category B

Paintings and inks

Same characteristics and procedures that it stops tipologia A, except:

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 15 mcd/m2 Luminance a 60 minutes ≥ 2,2 mcd/m2 Time of decadence ≥ 320 minutes

 

Signaling products

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 8 mcd/m2 Luminance a 60 minutes ≥ 0,7 mcd/m2 Time of decadence ≥ 110 minutes

Camera of saline fog

Without decrease of 5% it has more than enough values of luminance to the 96 hours of exhibition

Radioactivity

<74 kBq /kg

 

Category A

Glass

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 18 mcd/m2 Luminance a 60 minutes ≥ 2,8 mcd/m2 Time of decadence ≥ 340 minutes

Camera of saline fog

Without decrease of 5% it has more than enough values of luminance to the 96 hours of exhibition

Radioactivity

<74 kBq /kg

 

Category B

Glass

Same characteristics and procedures that it stops tipologia A, except:

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 15 mcd/m2 Luminance a 60 minutes ≥ 1,6 mcd/m2 Time of decadence ≥ 340 minutes

 

Category A

Fusible granules and Smeltings

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 28 mcd/m2 Luminance a 60 minutes ≥ 3,4 mcd/m2 Time of decadence ≥ 430 minutes

Camera of saline fog

Without decrease of 5% it has more than enough values of luminance to the 96 hours of exhibition

Radioactivity

<74 kBq /kg

 

Category B

Fusible granules and Smeltings

Same characteristics and procedures that it stops tipologia A, except:

 

Characteristic

Photoluminiscent under laboratory conditions

Luminance a 10 minutes ≥ 18 mcd/m2 Luminance a 60 minutes ≥ 2,5 mcd/m2 Time of decadence ≥ 410 minutes